Standard & Long Creeping Distance (also known as LCD or LLF) Micaver® Insulators are made with long time used lead-free Mica-glass composition. Mechanically and electrically robust, resistant to thermal shock, they are today the reference material for demanding applications such as in railway rheostatic brakes.

Main properties

Excellent vibration resistance and non-fragile behavior

As opposed to ceramic insulators, Micaver insulators are non-fragile and highly resistant to vibrations.

Resistant to thermal shock

Excellent resistance to thermal shocks from extreme winter temperature to high operating temperature (-40°C / +400°C).

Prevent most rusting issues

Standard Micaver insulators are commonly equipped with Nickel-plated Steel inserts. To further prevent most rusting issues in aggressive and salty enviroment, Micaver can also be offered with Stainless Steel 304L inserts which meet all the requirements of NF F 61-016.

Fire resistant

Micaver® insulators are classified A1 and therefore do not burn (EN45545-2).

Electrically insulating

Minimum insulation resistance of 1 TΩ.

Find your Micaver insulator

Height
Insert type
Insert material
Insert diameter
Creepage distance
Title Height (mm) Insert diameter (mm) Insert type Insert material Electrical rigidity (mn) Creepage distance (mm) Tensile strength (daN) Torsion resistance (daN.m) End flexural strength (daN) Datasheet
*MV LLF50 50 10 FF Nickel plated Steel 20 Kv/50 Hz/1 min 102 ≥ 1900 ≥ 4.5 ≥ 400
*MV LLF35 35 8 FF Nickel plated Steel 16 kV/50 Hz/1 min 70 ≥ 800 ≥ 2.3 ≥ 160
*MV LLF60 SS304L (M12) 60 12 FF Stainless Steel 304L 27 Kv/50 Hz/1 min 160 ≥ 1000 ≥ 8 ≥ 200
*MV LLF35 SS304L (M10) 35 10 FF Stainless Steel 304L 16 kV/50 Hz/1 min 70 ≥ 800 ≥ 2.3 ≥ 160
*MV LLF60 SS304L 60 10 FF Stainless Steel 304L 27 Kv/50 Hz/1 min 160 ≥ 1000 ≥ 4.5 ≥ 200
*MV LLF35 SS304L 35 8 FF Stainless Steel 304L 16 kV/50 Hz/1 min 70 ≥ 800 ≥ 2.3 ≥ 160
*MV LLF60 (M12) 60 12 FF Nickel plated Steel 27 Kv/50 Hz/1 min 160 ≥ 1000 ≥ 8 ≥ 200
*MV LLF35 (M10) 35 10 FF Nickel plated Steel 16 kV/50 Hz/1 min 70 ≥ 800 ≥ 2.3 ≥ 160
*MV LLF60 60 10 FF Nickel plated Steel 27 Kv/50 Hz/1 min 160 ≥ 1000 ≥ 4.5 ≥ 200
MV LLF50 SS304L (12M) 50 12 FF Stainless Steel 304L 20 Kv/50 Hz/1 min 102 ≥ 1900 ≥ 4.5 ≥ 400
*Special minimum order quantity & lead-time. Please conctact us for further information.

Search tool details

Creepage distance

Shortest distance along the surface of the insulator between two conductive inserts.

Insert type

Micaver insulators are made with 2 inserts which are described by type.

FF: Female/Female

MF: Male/Female

MM: Male/Male

Related markets

 
Industrial
Industrial
Trains, metro and trams using Micaver
Railway